High Efficiency Filters
The Features of Products
FFA Filter Grades
Reduces air inlet temperature and increases outlet temperature, preventing piping condensation.
Grade P
For coarse pre-filteration
Particle removal down to 3 micron
Grade U
For general filteration
Particel removal down to micron
Oil content down to 0.1 mg/m3 at 20°C
Grade H
For high performance filteration
Particle removal down to 0.01 micron
Oil content down to 0.01 mg/m3 at 20°C
Grade C
Activated Carbon Filter
For removal of oil content down to 0.003 mg/m3 at 20°C
in conjunction with filter Grade H.
Technical Data
● Maximum recommended operating temperature 60°C
● Minimum recommended operating temperature 1°C
● Maximum recommended operating pressure 16barg and 50 barg
● Maximum recommended pressure differential for element change is 0.35 barg. (Except Grade C)
● Material for FFA threaded type filters is aluminium.
● Filters come complete with auto drain (16bar) or manual drain (50bar).